Posted  by  admin

Behringer Dcx2496 Remote Software Download

Behringer Dcx2496 Remote Software Download Average ratng: 3,3/5 3423 reviews

DCX2496 ULTRADRIVE PC SYNC alakdan net. Behringer X32 - Use as a System. DCX2496 PC remote - Duration. 2 ULTRADRIVE PRO DCX2496/ULTRADRIVE DCX2496LE User Manual 3 ULTRADRIVE PRO DCX2496/ULTRADRIVE DCX2496LE User Manual Thank you Thank you very much for expressing your confi dence in BEHRINGER products. Oct 17, 2013 - The DCX2496 remote editor software V1.16a for Windows2000 or Windows XP is now available for download. This version ensures stable.

Miele w800 service manual. Download MIELE W800 SCH service manual & repair info for electronics experts.

Jan 27, 2018 - English grammar today pdf Free Download for WindowsTitle: English Grammar For Today Subject: english grammar for today Keywords. Murat Mar 24, 2018 - Dosya uzun bir sre hi. English Grammar Today Murat Kurt Pdf Reader. Business Planning for Mergers and Acquisitions: Corporate, Securities,. ENGLISH GRAMMAR FOR TODAY_2006.pdf - Download as PDF File (.pdf). Description: One of the best reference books for language teacher of English. A_an and the - English Grammar Today - Cambridge Dictionary.pdf.

  1. Free Pc Remote Software
  2. Dcx2496 Remote Software
Ultra-high precision digital 24-bit/96 khz loudspeaker management system.
Hide thumbs Also See for ULTRADRIVE PRO DCX2496
User manual - 36 pages
Quick start manual - 15 pages
User manual - 19 pages
1
Table of Contents
2345678910Software111213Behringer141516171819202122232425262728

Advertisement

Also See for Behringer ULTRADRIVE PRO DCX2496

Free Pc Remote Software

Behringer ULTRADRIVE PRO DCX2496 User Manual35 pages
Behringer ULTRADRIVE PRO DCX2496 User Manual35 pages

Related Manuals for Behringer ULTRADRIVE PRO DCX2496

  • Speakers Behringer ULTRADRIVE PRO DCX2496 User Manual
    Ultra-high precision digital 24-bit/khzloudspeaker management system (19 pages)
  • Music Equipment Behringer Ultradrive Pro DCX2496 Quick Start Manual
    Ultra-high precision digital 24-bit/96 khz loudspeaker management system (15 pages)
  • Stereo Equalizer Behringer ULTRADRIVE PRO DCX2496 Quick Start Manual
    Ultra-high precision digital 24-bit/96 khzloudspeaker management system (13 pages)
  • Music Equipment Behringer V-VERB PRO REV2496 Quick Start Manual
    A reference-class reverb modeler & an ultra high-precision digital 24-bit/96 khz eq/rta mastering processor & the ultimate digital loudspeaker management system (3 pages)
  • Music Equipment Behringer DI4000 User Manual
    Behringer spezielle stud users manual mixer di4000 (14 pages)
  • Music Equipment Behringer VIRTUALIZER PRO DSP2024P User Manual
    Behringer virtualizer pro user's manual dsp2024p (40 pages)
  • Music Equipment Behringer ULTRA-DI D 100 User Manual
    Ultra-rugged di box for stage and studio (15 pages)
  • Music Equipment Behringer EDISON EX1 User Manual
    Stereo image enhancer/phase corellation meter (34 pages)
  • Music Equipment Behringer MX882 User Manual
    Behringer spezielle studiotechnik 8-channel signal router users manual ultralink pro mx882 (16 pages)
  • Music Equipment Behringer Composer MDX 2100 User Manual
    The audio interactive dynamics processor (7 pages)

Summary of Contents for Behringer ULTRADRIVE PRO DCX2496

  • Page 2: Table Of Contents

    This manual was created to facilitate better understanding of how the DCX2496 remote software works when used with multiple units. It will help answer questions about synchronization, link modes and remote software handling. Apart from that, it gives simple examples about what to do when connecting and synchronizing one or more DCX2496s to a personal computer for using the DCX remote editor software.
  • Page 3: General Tips

    RS-232 RS-485 Before you launch the remote software, you first have to select the correct link mode on SETUP page 6/6 (behind the entry “PORT”) on the DCX2496(s) hardware. Here you can select between three modes: and 2 DCX2496 for PC editing..………..……………page 19 DCX<RS485>2..
  • Page 4 In this mode, you connect the first DCX2496 to the COM port of your PC via a RS-232 cable; the 2 via the LINK connectors A or B on the rear of each DCX2496. It doesn’t matter if you … DCX2496 is daisy chained via the..
  • Page 5 LINK A or B, both connections are parallel. The first and the last DCX2496 with an RS-485 (!) connection has to be terminated (back: TERM = ON), the DCX2496s in-between have to be set to TERM = OFF. In the example below, the units 1 and 3 have to be set to TERM = ON, the middle unit 2 has to be set to TERM = OFF.
  • Page 6: Detailed Explanation Of The 'connect' Page

    The most frequent source of error in communication between the PC remote software and the DCX2496 hardware are wrong settings of DCX2496 parameters DEVICE ID and PORT on the hardware (described above) as well as incorrect usage of the PC software in CONNECT menu (described below).
  • Page 7 “Recognized Devices” & “Device Information” On the left window “Recognized Devices” you can select the particular DCX2496 that you wish to edit. In this example, there is only one unit, called “DCX2496,” so you can’t select another DCX2496. On the right you will find the “Device Information” of the selected “Recognized Device.”..
  • Page 8 DCX2496. o “Direction: PC->DCX2496” is used only to store the current PC settings to the DCX2496, or if you want to transmit the data edited offline to the DCX2496. o With the three “Data” clickable boxes, you can select what kind of data should be transmitted from/to PC: only the current set or all presets from internal bank or card bank.
  • Page 9: Quick Info About Standard Handling

    --------------- o HINT: Normally you should stay in “Direction: DCX2496 -> PC” mode and select “Stay Synchronized.” This way, you can edit from your computer and also in the hardware. More about this subject can be found in the remote editor software’s help file (press F1 on your PC while the..
  • Page 10 Under “Synchronizing,” check … o only “Current Set” if you wish to edit the running preset only o “Current Set” + “Internal Presets” if you want to load the DCX2496 internal memory bank to the remote software as well o all three check boxes (including “Card Presets”) if you want to dump the card presets to your computer as well o ATTENTION: If you select “Card Presets”..
  • Page 11: How To Backup Your Dcx2496 On The Pc

    ATTENTION: If you checked the “Card Presets” box and the PCMCIA card inside your DCX2496 is not formatted, you will get an error message if you try to synchronize If you now wish to make parameter changes on your second or third DCX2496, please go back to “Connect”..
  • Page 12: How To Copy Dcx2496 Data To Another Dcx2496

    Copying of all data from DCX2496 #1 to DCX2496 #2 is finished -------------------------- Example 1: PC to 1 DCX2496 via RS-232 1. Connect the DCX2496 via the RS232 port with a standard 9-pin RS232 cable to a COM port of your computer. 2. Power up the DCX2496 and the PC.
  • Page 13 5. Go to the “Connect” page 6. If the DCX2496 hardware was not found automatically, change the “Communications Port” and click “?Search DCX2496s.” 7. Now you should see the following screen:..
  • Page 14 8. You have different “Synchronizing” options: Loading Presets and/or the current set from the DCX2496 to the PC: o Select the “Direction” DCX2496 -> PC o Select the “Data” you wish to transfer (Current Set and/or Internal Presets and/or Card Presets) o Click “Synchronize”..
  • Page 15: Example 2: Pc To 1 Dcx2496 Via Rs-485

    TIP: In the above screenshot the “DCX2496” has been renamed “My Main DCX #1.” Example 2: PC to 1 DCX2496 via RS-485 1. Connect the DCX2496 via the RS485 port (LINK A or B) with the RS-485 card on your computer and set the TERM switch on the DCX2496s rear to “on.”..
  • Page 16 7. Now you should see the following screen: 8. You have different “Synchronizing” options (identical to Example 1): Loading Presets and/or the current set from the DCX2496 to the PC: o Select “Direction” DCX2496 -> PC o Select the “Data” you wish to transfer (Current Set and/or Internal Presets and/or Card Presets) o Click “Synchronize”..
  • Page 17 Then click “Synchronize” and wait until the transfer is complete Then click “Return” to go back to the main editor Please keep the “Stay Synchronized” box always active! TIP: In the screenshot, the “DCX2496” has been renamed “My Main DCX #1.” __________________________________________________________________________..
  • Page 18: Example 3: Pc To 2 Dcx2496s (pc1 St Dcx2 Nd Dcx)

    1. Connect the first DCX2496 via the RS232 port to the COM port on your computer. 2. Connect the first DCX2496 via its LINK A (or B) port (RS485) to the LINK A (or B) port (RS485) of the second DCX2496.
  • Page 19 9. a) If both DCX2496s were not found automatically, change the “Communications Port” and push “?Search DCX2496s.” b) If only one DCX2496 was found automatically, push “?Search DCX2496s” (without changing the Communication Port). 10. Now you should see the following screen:..
  • Page 20 A EQ curve of preset 20 at DCX2496 ID 2 Preparation: To check the correctness of changes on the DCX2496 displays, select IN A and then page 3/5 (“IN A -> EQ 3/5”) on both DCX2496s.
  • Page 21 1. Rename both DCX2496s to “First Device” (the DCX2496 with ID 1) and “Second Device” (the DCX2496 with ID 2) by clicking on the text behind “Name.” This way, you can easily identify both DCX2496s. The individual names are stored on the DCX2496 hardware even after you power them down, so these names will appear even when you start the remote software again (even on a different computer).
  • Page 22 With “Quick Synchronize to DCX,” the PC software receives all the information (parameter settings) from the current DCX2496#1 preset directly sent from the hardware (in our case “preset 19 > F1220”). Now the screen looks like this: If you now move the small white rectangle in the curve using the mouse, you can see the curve instantaneously changing on the DCX2496 LCD as well.
  • Page 23 Internal Presets” > and then selecting the desired preset. b) If you want to use one of your own user presets stored in the internal memory of the DCX2496#1, please do the following: Select the following items on the “Connect” page: Then, click “Synchronize”..
  • Page 24 Here you can also clear or lock presets. --------------------------------------------------------- Procedure 2 (Edits on DCX2496 ID 2): First we have to change the PC remote control mode from Device ID 1 to ID 2. 1. Go to the “Connect” page 2.
  • Page 25 5. Select EQ page, IN A button and then “Quick Synchronize to DCX” Using “Quick Synchronize to DCX,” the PC software gets all the information (parameter settings) from the current DCX2496#2 preset directly from the hardware (in our case “preset 20 > F1520”).
  • Page 26 Example 4: PC to 2 DCX2496s (PC<RS485>1 1. Connect the first DCX2496 via its LINK A port (RS485) to the RS485 port of your PC card. (This will only work with a true RS-485 card, not a standard network card like those found in laptops!) DCX<RS485>2..
  • Page 27 2. Connect the first DCX2496 via its LINK B port (RS485) to the LINK A (or B) port (RS485) of the second DCX2496. 3. Push the TERM switch only on the second DCX2496 to ON. 4. Power up both DCX2496s and the PC.
  • Page 28 BEHRINGER Spezielle Studiotechnik GmbH. BEHRINGER is a registered trademark. © 2003 BEHRINGER Spezielle Studiotechnik GmbH.
Hello!
I have several Behringer DCX2496 digital crossovers (that splits in audio signals sending out bass signal to bass power amps, mid signals to mid power amps, high signals to high power amps) for my very big PA.
Now, these crossovers can be remotely controlled by PC software that I have downloaded from Behringer's download service.
To be able to run this PC program on my Imac I have got myself the CrossOver software (quite funny incidently also called crossover) inside which I can run Windows program.
The remote control PC software starts up just fine but it does not be able to find my connected DCX2496(s) - the DCX2496s have both RS232 (serial port) connection and RS485 (network cable) connection - I have tried to connect an RS232/USB adaptor cable from RS232 connection on DCX2496 to USB connection on my Imac as well as network connection on DCX2496 to network connection on my Imac - but nothing happens simply!
What to do? (Admittely a quite special question, but perhaps someone else out there has got this working?)
Best, palbin

imac, Mac OS X (10.5.5)

Dcx2496 Remote Software

Posted on